Troubleshooting Vacuum and Tumble Marinator emergency stop button

Difficulty: Intermediate
Time Required: 5-10 Minutes
SAFETY MESSAGE
Before conducting maintenance, power Marinator off and disconnect from power source.

Tools Required

Phillips-head screwdriver
Knife

Replacement Parts Needed

OVERVIEW VIDEO

Watch the entire process by clicking the video to the right, or continue scrolling for step-by-step instructions.

WATCH VIDEO

Check to see if emergency stop button has been activated.

  1. Lightly turn the red emergency stop button clockwise to release it.
  2. Test unit to see if the issue has been resolved. If not, continue troubleshooting.

Open internal housing.

  1. Ensure that the Marinator is powered off and unplugged.
  2. If the Marinator has never been opened, slit the silicone seal around the base with a knife or other sharp blade, cutting away from your body to avoid blade-related injuries.
  3. Unscrew all 4 screws around the top perimeter of the housing and remove the top plate.

Modify internal wiring to bypass emergency stop button.

  1. Locate the internal side of the emergency stop button, a small red plastic part connected by one blue and one black wire.
  2. Slightly loosen the screws that hold the wires in place.
  3. Remove the black wire on the left and mount it on the same screw as the blue wire on the right.
  4. Tighten both screws.

Test emergency stop bypass.

  1. Plug Marinator back in and start unit.
  2. If the Marinator starts, the stop button is faulty and needs to be replaced.

Replace emergency stop button.

See related guide.

Additional Video

Here you’ll find a “Quick Tip” video on how to properly use the emergency stop button.

WATCH VIDEO